Features of the Elnur MAS15 Electric System Boiler

Auto Heating Modulation

Our MAS15 boiler automatically modulates the amount of watts required to meet the specific heating demand, as needed. It will never go above the pre-set watt maximum, meaning it is as cost effective as possible.

Our MAS15 Electric Boilers

Our MAS15 wall mounted boiler is a heating only boiler, compatible with the Elnur Connected Range.

Elnur MAS15 Electric Combi Boiler

Silent TRIAC Power Switches

Coming away from mechanical switching, our next generation TRIAC switch ensures a smoother and quieter modulation.

Technical features.

Dimensions and Specifications

MODEL MAS15
Selectable Output kW
3
4
5
6
7
8
9
10
11
12
13
15
kcal/h
2580
3440
4300
5160
6020
6880
7740
8600
9460
10320
11180
12900
Current 3 x 400 V+N~ A
13.0
8.7
13.0
8.7
13.0
13.0
13.0
21.7
21.7
21.7
21.7
21.7
*Current 230 V~ A
14.0
17.4
21.7
26.1
30.4
34.8
39.1
43.5
47.8
52.2
Ask
Ask
MODEL MAC15
Voltage V
3x400 V+N / 220-240
Frequency Hz
50
Insulation
Class 1
Net weight kg
29.5
Dimensions(HxWxD)
76cm x 35cm x 26.5cm
EAN13
8432336804700

*Using included bridge connection

Technology

General Lifestyle Image

Self Regulation

Our Mattira electric boilers are unique in that they regulate energy consumption according to the heating needs of the installation. They take into account the room temperature, making it an even more comfortable boiler.

Connectivity

Connectivity in home heating can be completed by using any chronothermostat from the CTM WiFi range. This accessory allows you to remotely manage the boiler through the G Control System.

FAQs

We would suggest firstly to check the set point temperature of the boiler, this could be set low and just needs to be increased this can be done via the plus key on the left hand side. Secondly I would suggest the Mixer valve is checked and increased as if this is too low then it can cause the water to only come out lukewarm. Increase the setting and test again.

If your heating is not working we would suggest checking your thermostat. The test for this would be to turn the thermostat above your usual temperature and see if the boiler starts up. If the boiler does not come on it is most likely a thermostat issue and it will need to be replaced. If the thermostat is working and is calling for the boiler to heat, check to see if the boiler is showing a temperature and that the boiler pressure is at 1.5 bar, if not refill using filling loop underneath. If your boiler is still not providing any heating after trying the above please call our technical line on 01942 670119 or email technical@elnur.co.uk

The modulating operation of Elnur Gabarron electric boilers is managed by an Intelligent Control Electronic Modulation System (EMS), which will regulate the output according to actual heat demand. The boiler will work for longer at minimum power and carry out fewer on/off operations, saving electricity consumption, compared with a system without modulation.

In order to modulate the boilers, an external thermostat must be connected. Modulation only occurs for the heating circuit, not for heating domestic hot water.

Unlike gas boilers, electric boilers do not require any sort of compulsory maintenance. We, as the manufacturer, recommend the boiler’s power cables, electricity consumption and pressures to be checked.

Want to know more?

Enquire about our Mattira MAS15 range of Electric Boilers today!